Furnace Transformer:
Main Functions and Features
An electric furnace transformer is used to supply power to an electric furnace, which lowers the high voltage to the furnace-required lower voltage.
Its type varies with the type of electric furnace, so the transformer has many types. Currently we manufacture following types: Arc furnace transformers used for steel-smelting (including load-ratio voltage regulator type, no-load voltage regulator type, and built-in reactor type); Blast furnace transformers used for smelting of iron alloy, silicides, calcium carbide (single phase, three phase, load ratio voltage regulator and no-load voltage regulator). All are energy-saving products with low power loss. The cooling modes are self-cooling mode, forced water cooling mode, etc;
on-load-tap-changing Arc Furnace Transformers Technical Parameters;
Rated power (KVA) | Primary Voltage (KV) | Secondary Voltage (V) | Secondary Step Voltage (V) | Rated Secondary Current (A) | Regulation Voltage Step | Connection symbol | short-circuit Impendance(%) | Cooling Method | |
Invariablenes Power | Invariablenes Current | ||||||||
10000 | 35 66 | 280~240 | 240~100 | 10 | 24 056 | 5 Steps Invariablenes Power, 14 Steps Invariablenes Current | Ddo Yd11 Ynd11 | 7~8 | OFWF OR OFAF |
12500 | 314~270 | 270~116 | 11 | 26 729 | |||||
16000 | 353~305 | 305~137 | 12 | 30 287 | |||||
20000 | 35 66 110 | 392~340 | 340~158 | 13 | 33 962 | 6~7 (35KV) 7.5~8.5 66110KV | |||
25000 | 436~380 | 380~184 | 14 | 37 984 | |||||
31500 | 489~425 | 425~201 | 16 | 42 792 | |||||
40000 | 547~475 | 475~223 | 18 | 48 619 | |||||
50000 | 610~530 | 530~250 | 20 | 54 467 | |||||
63000 | 673~585 | 585~277 | 22 | 62 176 | |||||
80000 | 760~660 | 660~310 | 25 | 69 982 |
Type | Rated Power (KVA) | Connection symbol | Primary Voltage (KV) | Secondary Voltage (V) | Regulation Voltage Step | short-circuit Impendance(%) | No-Load Loss | On-load Loss | Weight (T) |
HSSPZ- 10000/35 | 10000 | Yd11 | 35 | 300~160 | 13 | 8.5 | 12 | 97 | 26 |
HSSPZ- 16000/35 | 16000 | Yd11 | 35 | 375~200 | 15 | 8 | 16.4 | 16.1 | 36 |
HSSPZ- 20000/35 | 20000 | Yd11 | 35 | 400~270 | 13 | 7 | 20.7 | 207.7 | 40.5 |
HSSP- 25000/35 | 25000 | Yd11 | 35 | 509~302 | 13 | 7.5 | 28.5 | 273.6 | 49.6 |